For over two decades, K-Tech International has provided worldwide the NYLOAD® Intelligent Load Weighing System. This cost effective load weighing solution is ideal for all traction elevator environments including both isolated and non-isolated cabs. Now we present the next step in elevator load weighing, the...
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
Interface With Virtually Any
|
K-Tech load weighing is ideal for both modernization and new construction of traction elevators. Using crosshead mounted strain gauge technology, the deflection sensor is designed to work on both isolated and non-isolated cabs.
There is no need for any cab renovation, such as replacement of isolation pads or re-squaring, since these factors do not affect the bending of the crosshead under the strain of the load. Additionally, installation does not require major work, like jacking up the cab off the frame, so it can be easily completed in one day.
The initial installation of any load weighing system is the most critical part of a successful application. The design of the K-Weigh incorporates several innovations to make it easier to do it right the first time:
Automatic Reset ensures that settings stay put. The K-Weigh will maintain the original calibration and eliminate measurement errors from emergency stops, seasonal temperature shifts, and other changes to the car's frame.
Automatic Reset can be triggered automatically through a signal from the elevator controller, or manually by a simple button press.
Enclosure: |
steel NEMA Type 1 (standard) |
Sensor(s): |
1"H x 7"W x 1/4"D (26 mm x 178 mm x 6.4mm) bar; 8' (2.4 m) cable |
Power Input: |
100 - 240 VAC, 47 - 63 Hz; 0.6 A @ 115 VAC; 0.45 A @ 240 VAC |
Output: |
1 - 8.5 VDC (Analog system) |
Resolution: |
< 50 lbs (< 23 kg) or 2% (typical installation) |
Repeatability: |
< 2% |
Temperature: |
32 to 158°F (0 to 70°C) |
Humidity: |
20 - 85% non-condensing |
Drift/°F: |
0.3% of FS (typical, without Auto Reset) |
Zero Reset: |
< 1% |
Correction: |
± 40% offset (~ 4 VDC) |
Input: |
120 VAC ground (pull-down) |
Approvals: |
ETL (UL & CSA) Safety |
Compensator Module |
|
Input: |
Requires NO/NC contact closures for UP and DOWN direction and FLOOR COUNT (or optional UP and DOWN COUNT); up to 64 counts (standard) (Pulse width: minimum 10 ms for NO contact, 120 ms for NC contact (NO/NC between floors)) |
Output: |
0 - 5 VDC signal into 1 KΩ load |
Set Point Module |
|
Adjustments: |
0 - 100% of maximum load |
Output: |
Two independent DPDT NO/NC contacts rated 10 A - 28 VDC; 1/4 HP - 120 VAC |
Bypass Module: |
|
Adjustments: |
Set and Reset 0 - 100% of load (Reset < Set) |
Output: |
Single DPDT NO/NC contacts rated 10 A - 28 VDC; 1/4 HP - 120 VAC |
Lock Out Relay Module: |
|
Input: |
Requires 120 VAC @ 50/60 Hz (typically from elevator door switch) |
Output: |
Single DPDT NO/NC contacts rated 1/3 HP - 120/240 VAC |
To configure the most cost effective load weighing solution for your unique |
You will need to download Adobe Acrobat Reader to view PDF files.